LMCSS CONTRACT PARAMETER FOR AAA30085AAF

  Installation Parameters (2-3-1)

  Top floor _________----Enter top landing minus one

  Bottom floor _________Lowest landing is always 0

  Country AJG _________Enter 0 for NAA, 1=JAPAN,2=GERMANY

  Enable ADO__________Set to a 1 to enable Advanced Door Open feature

  DBSS parity OE____1_____Drive Dependent Prity Flag –

  set to a 1

  Car non start _____30__Length of time for a normal high speed run without seeing a DZ signal

  Track err% NOR ______15______Set to 15 after Final adjustment

  NTSD cutoff% _________ set to 60 initially ,reset during adjusting of NTSD

  Upper Access Flr _______ Enter landing number of top access floor

  ED car ID____0_____ set to elevator number in group for enhanced diagnostics,REM

  Elev type _______enter 8 for GEM,9 for MVS & HVS

  Dual ANSI SC brd _____0____

  LSP Type ____0_____Can.B44:Enter “1” with rope grabber

  Enter “2” with Gov. Trip soleniods Enter 0 for NAA operation

  Ena CEN_HONGKONG _____0____ENTER 1 for CEN-HongKong controller

  Ena pvt check ____2____

  Track. Debnce cyc ____8____

  MCSS to OCSS ICD _______0___ Enter 1 for B44 & DLF operation on NAA controllers after 8/1/97

  Ena B44 DLF _______0____Enter 1 for B44 & DLF operation on NAA controllers after 8/1/97

  ADV PTR option ____0___ HVS=10

 Install2 (2-3-2)

  Ena Dir Lim NY __0_____N=0,Y=1,Enable software direction limit

  Rotate DIR NY______0___N=0,Y=1,Reverse PVT direction information from DBSS

  Adv PTR Holdoff ___0_____Advanced prepare to run holdoff (100 ms),10-forgeared,0-for gearless

  Wrt Prot Opt NY ____0____N=0,Y=1,Enable running the elevator with the write protect switch enable

  Enable prejerk Vel_____0______ Not used on VF Drive

  Prejerk Ramp Cyc ____7____

  -----------------Dlt ____3______

  DOOR COMM TYPE ____0_____DCSS(pnt –pnt)=0,Multidrop=1,Multidrop W/HPLIM=2注意HPLIM设为0

  REM Enable _____0_____W/0 REM=0,W/REM=255(ENABLE/DISABLE)

  REM Event Buffer _________0___ W/0 REM=0 W/REM=255(enable/unable)

  REM Tim Event Ln ___5______ # of 100msec cycles

  REM BAUD Rate _____48____ 4800 baud (only)

  REM Msg Sumcheck _____255___ W/0 REM =0,W/REM=255(enable/disable)

  Profile generator(2-3-3)

  Velocity normal __________ Enter contract speed in mm/s

  Accelera Normal _____ Enter 600 for all GEM & MVS 5035 duty :1000 for all other MVS/HVS duties

  Jerk Normal ___1560____

  *

  Velocity Inspect _____350____

  *Accelera Inspect ___600___

  *Velocity Learn ____150____

  *Accelera Learn __600____

  Velocity Relevel __60____

*Accelera Relevel _____300____

  Velocity Recover _250_

  *Accelera Recover ___600____

  *Velocity Slow ____150____

  Velocity Reinit _____900___

  Accelera Reinit ________Enter 600 for all GEM & MVS 5035 duties 1200 for all other MVS/HVS duties

  Accelera NTSD ___________Enter 800 for GEM & MVS 5035 duties 1200 for all other MVS/HVS duties

  NTSD Comp Distance ________Enter 200 for 1016 mm/s contract speed

  Jerk timed __0_____

  Velocity reduced ____700_____

  Accelera reduced __600______

  Jerk reduced ___600_____

  Velocity profile 2 _1000____

  Accel profile 2 _____600______

  Jerk profile 2 ____1560_____

  Velocity profile 3 __1000______

  Accel profile 3 __600____

  Jerk profile 3 ___1560____

  Velocity test __1000_____

  Acceleration test _600____

  Jerk test ____1560______

  Velocity zero ___1____

  JPSDO type ____0______

  Velocity JPSDO_____0____

  *Gain fixed posct ______25_____

  *Delta TC ___240____Minimum setting for VF drive

  Decel/accel % _____100______

  Destination Lead _____0____

  Destination Lag______0______

  Level tolerance __3_____

  Zero speed time ____500____

  BKL to Mov time ___0__

  EOR PTR time ___0____Without Brake swicth,set to 5

  Relevel delay_____50_____

  CAB HEIGHT _2500____Set distance in mm to stop car with cross-head level with tp access ldg.level.

  Bot ACCESS LEN ___2500____Set distance in mm,when set to 65535,bottom access length is set to full length of hoistway.

  Position displmt ____0______

  1LS/2LS tolerance _____300____

 

Slippage tolerance _200_____

  Counts per revol ____________Enter 1024 for MVS/GEM 10000 for HVS

  Motor speed _______See following table;enter motor rpm

  HVS Gearless-156 MST Machine 24” drive sheave *

  Contract Velocity

  Motor RPM

  2540 mm/s(500 fpm)

  159

  For other arrangements see formula on page 30 to calculate the “

  Motor RPM”.

  *Motor Base speed ________set to 80% of contract speed mm/s.

  *Velocity Access __250_____Velocity for access operation in mm/s

  *Prejerk Pos Delt _____0______Stiction Comp. PVT counts before motion (not used on VF Drive).

  Landing Assignments (2-3-5)

  Enter a”1” under the column for the appropriate door at each landing

  Load Weighing parameters (2-3-6)

  Load device type ____4_____

  OCSS load enable ___1______

  DBSS load enable _______1_____

  DBSS ANS Load % ______10_____

  DBSS Deflt load% ____40______

  DBSS Peak load% ___60______

  DBSS Full load% ____80______

  DBSS Overload% ____125_____

  Offset adjust __________ DI